PAWS Tracking Results for Cycle 1 for 2000/2001



 


 

Item Number

Group Number

Date PAWS Form Filled Out

Unsafe Act / Situation / Suggestion

Action Taken/Safety Suggestion

Person Responsible

Open / Closed

Comments

Cycle 7

 

 

 

 

 

 

 

1

8A

9/19/00

Valve LHXV-13 has a slight leak from the handle. This is on the shell and tube heat exchanger experiment

To promote safety, valve should be looked at, and possibly replaced.

 

Closed

 

2

11A

9/19/00

Thermocouple is broke (Heat Exchanger: Ammonia Cooler/Jacketed Heater). Plastic and wires frayed. Missing pieces.

Contacted Tim Gasperich and safety group. We used electrical tape to repair, until a new thermocouple was available.

 

Closed

 

3

11A

9/19/00

Heat Exchanger: (Ammonia Cooler & Jacketed Heater) water inlet handle is too high. (A ladder will not fit into space to turn handle). Alternate method was needed.

Used a cinder block to stand on to reach. Told safety group and T.A.

 

Closed

 

4

12A

9/19/00

Exposed cord on strobascope for Pumping A

Get replacement cord – Repaired by Chem. Eng. Shop

 

Closed

 

5

12A

9/19/00

Fire extinguishers not inspected since 5/23/00 – must be inspected every month.

Inspected all the extinguishers in lab.

 

Closed

 

6

2B

9/21/00

For Vacuum Dryer, thermocouple #10 does not work. It shows a negative infinite temperature

 

 

Closed

 

7

3B

9/21/00

Gloves had a hole in the finger when student was using them to open/close a steam valve

Find a new pair of protective gloves to prevent burn

 

Closed

 

8

3B

9/21/00

Steam valve was leaking and group was unaware of drip – small puddle on floor could have been slip problem if continued

Put pail under dripping valve or check valve for leak

 

Closed

 

9

3B

9/21/00

Student was getting materials out of oven without gloves on

Asked the person to put on my gloves before getting more out of oven

 

Closed

 

10

5B

9/21/00

Viewed from second floor – person left room B005A without safety glasses to view check-in sheet

Person remembered themselves – also I could not contact the person from 2nd floor. A sign near that door might help people remember if they do take them off

 

Closed

 

11

5B

9/21/00

Chemical cabinets left open in room B005B. No person was near by when I went in.

Closed cabinet. Suggest sign on inside to close cabinet when finished

 

Closed

 

12

5B

9/21/00

Pump in continuous filtration does not have a proper seal so slurry leaks onto floor causing slip hazard

Maintained clean area around experiment with squeegee and mop

 

Closed

 

13

7B

9/21/00

Flow measurement – room 213. The foxboro meter’s electrical connection, black wire, has damaged plastic coating at wire/meter connection point

Tape location with electrical tape or replace connection

 

Closed

 

14

7B

9/21/00

Flow measurement – room 213. Valves V62, V8, V25, V3 leak

Fix them

 

Closed

 

15

8B

9/21/00

Person carried chemicals and bottle in hand across room from flammable storage to LLE

Had them get a transporting bucket

 

Closed

 

16

10B

9/21/00

Student at capillary viscometer took off his hard hat

Told him to put it back on

 

Closed

 

17

10B

9/21/00

Fluidization sieve analysis, the sieves are bent and some jam very tightly, I could have hurt myself prying them apart and the jolt affected results by dumping a little material

I suggest $3000 for new sieves or removal or reforming of bent ones

 

Closed

 Use a screwdriver.

18

1A

9/26/00

On manometer, high and low values were open and the bypass was closed when we got here today.

Make sure they are in right position when checking out of lab. 

 

Closed

 

19

6A

9/26/00

There are big holes in the yellow work gloves in the thumb and middle fingers. Not good when handling hot things.

Threw out the gloves

 

Closed

 

20

8A

9/26/00

Potential hazard – within only a few seconds, 30 psi steam through the heat exchanger will cause the thermometer to ramp up near their 240° F max. The idea of a preheat is not possible unless water flow is also present. 

Suggestion is to add the major safety precaution to the objective handouts.

 

Closed

 

21

9A

9/26/00

On cooling tower, water leak coming from above H20 flow meter

Tightened hose clamps. Still a small amount of leakage. Hoses look old, may need replacing.

 

Closed

 

22

11A

9/26/00

Heater exchange (Ammonia Cooler & Jacketed Heater) Valve isn’t labeled.

Told safety group and T.A. Valve isn’t used in process, but need to have an I.D. tag

 

Closed

 

23

11A

9/26/00

Heater Exchanger (V-24) single pass ammonia cooler. Valve is leaking steam, very minor.

Told safety team.

 

Closed

 

24

11A

9/26/00

Heat Exchanger – Ammonia Cooler / Jacketed Heater. Steam pipes should be covered. All of them should have insulation.

Told safety group. Used caution when handling steam valves and pipes.

 

Closed

 

25

11A

9/26/00

Individual was wearing hard hat backwards, while joking around. (Pumping "A" Experiment.)

Told individual to put his hat on properly.

 

Closed

 

26

11A

9/26/00

Leaking valves (Heat Exchanger: Jacketed and Ammonia Cooler). V-19, V-21 both leak a lot.

Asked T.A. "Don’t worry about it." Told safety group.

 

Closed

 

27

12A

9/26/00

Large size nitrile gloves box empty in UO lab office.

Told TA, who went and got another box from chem-stores.

 

Closed

 

28

12A 

9/26/00

Group doing the vacuum drying experiment had 3 stools in the basement aisle.

Moved stools for them and told them to keep stools out of the aisle. 

 

Closed 

 

29

12A

9/26/00

Student was chewing gum in lab on 1st Floor.

Told student to dispose of it and he threw it out immediately.

 

Closed

 

30

12A

9/26/00

Ipecac syrup is expired (10/97) in 1st floor first aid kit.

Told TA, was told to tell Tim.

 

Closed

 

31

12A

9/26/00

Group CSTR spilled H2O all over floor and wasn’t cleaning it up.

Told them to clean it up immediately.

 

Closed

 

32

4B

9/28/00

CSTR Rotameter #1 (Phenol) ball is sticking. Needs to be cleaned and recalibrated

 

 

Closed

 

33

8B

9/28/00

T by V-24 on single pass heat exchanger is leaking steam and water

Not serious, recommend Tim or Dave check equipment

 

Closed

 

34

8B

9/28/00

Lack of labeling for oil chemicals in B005 office

Label or move to other location

 

Closed

 

35

12B

9/28/00

Aprons are too long, I almost tripped over it.

Cut them shorter

 

Closed

 

36

12B

9/28/00

Switch on L-L Ext Pump is loose

Put in new or fix switch

 

Closed

 

37

13B

9/28/00

Methocel is 10 years past expiration (use by) date. Is health rating the same after decomposition?

Dispose of and buy new

 

Closed

 

38

12A

10/2/00

There are 6 or 7 mercury manometers just leaning against the wall in the storage room B005A

Remove mercury from manometer and place U-tube in safer location

 

Closed

 