Item Number |
Group Number |
Date PAWS Form Filled Out |
Unsafe Act / Situation / Suggestion |
Action Taken/Safety Suggestion |
Person Responsible |
Open / Closed |
Comments |
Cycle 5 |
|
|
|
|
|
|
|
1 |
9A |
10/17/00 |
Railing at bottom of spiral staircase is loose (missing screw) |
Suggest replacing screw (tightened remaining screw) |
|
Closed |
|
2 |
3A |
10/17/00 |
Leaky steam valve V-1 (Cooling Tower Experiment) |
Told Tim, suggest tightening |
|
Closed |
|
3 |
3A |
10/17/00 |
Cooling Tower, lower right gasket leaking |
Take out rubber piece and put in metal piece like the rest |
|
Open |
|
4 |
1A |
10/17/00 |
Heat Exchanger: (NH3 Cooler) valves V-19, V-21, & V-20 all leak |
Suggest fixing |
|
Closed |
|
5 |
9A |
10/17/00 |
No health label on Reactor Mixer Gearbox Oil & SSR ultra coolant in B005A |
Label Materials |
|
Closed |
|
6 |
9A |
10/17/00 |
Carrying paper towels in both hands up spiral staircase |
Warned group |
|
Closed |
|
7 |
9A |
10/17/00 |
Transporting glassware without bucket |
Alerted group |
|
Closed |
|
8 |
9A |
10/17/00 |
2 group members weren't wearing earplugs while running the cooling tower |
Told students that ear protection was required |
|
Closed |
|
9 |
9A |
10/17/00 |
Student was wearing clothing that had long loose strings |
Told student to tuck them in |
|
Closed |
|
10 |
11A |
10/17/00 |
Heat exchanger (ammonia cooler) large drums with liquid, no label. Group left unattended. Spill equipment was leaning on operating equip. |
Told group |
|
Closed |
|
11 |
1A |
10/17/00 |
Napkins shoved in googles (eye hazard) |
Asked student to remove. Reported to safety group |
|
Closed |
|
12 |
9A |
10/17/00 |
Group needs to sign out when they leave lab for lunch |
Remined group to do so |
|
Closed |
|
13 |
9A |
10/17/00 |
Barrel left over drain hole. Warned group during lab and they fixed it the problem. The barrel was over the drain again after they checked out. |
Moved barrel |
|
Closed |
|
14 |
11A |
10/17/00 |
Fludization- Tray in B005 B (Ro-Tap) equipment tray dia .0138 has a hole in it |
Patched with duct tape |
|
Closed |
|
15 |
9A |
10/17/00 |
Discrepency of the Dow Endblock A labels |
Changed all labels to be the same |
|
Closed |
|
16 |
9A |
10/17/00 |
Transporting Glassware without a bucket |
Told student to carry glass in a bucket |
|
Closed |
|
17 |
9A |
10/17/00 |
Non-Newtonian flow group continues to carry glassware w/out a bucket |
Told this group again not to carry glass w/out a bucket |
|
Closed |
|
18 |
6B |
10/19/00 |
Single pass heat exchanger ammonia cooler- leaking valves and not enough barrels with holes in the bottom. Water splashes out onto the floor. |
Provide more barrels with holes, provide aprons so people don't get so wet, make sure valves are not leaky(V19, V20, V21) |
|
Closed |
|
19 |
|
10/19/00 |
Valve 11UHX on upper heat exchanger is broken |
Replace valve with new one |
|
Open |
|
20 |
1B |
10/19/00 |
There are several MSDS's missing from UO lab book (water, steam, wood chips). This book should have all the MSDS for the chemicals in lab |
Get them |
|
Closed |
|
21 |
10B |
10/19/00 |
Non-Newtonian flow exp., the outlet water pipe leaks next to electrical cords |
Fix leak at connector to the coil in the cooling bath |
|
Closed |
|
22 |
4B |
10/19/00 |
Non-Newtonian flow-opened valve too quickly. Manometer overflowed and mercury spilled |
Got tim to clean up. Reminded to open slowly. |
|
Closed |
|
23 |
3B |
10/19/00 |
Person left oven door open and left to talk to someone. Burn hazard |
Told person to shut door next time when leaving. I shut it for them. |
|
Closed |
|
24 |
3B |
10/19/00 |
Carried a beaker up spiral staircase |
Pointed out sign to her and gave a polite reminder |
|
Closed |
|
25 |
3B |
10/19/00 |
Student did not tie her apron proceded to walk up 2 steps carring a beaker |
Told her not to do that & tied the strings |
|
Closed |
|
26 |
4B |
10/19/00 |
Student was sitting in aisle on the floor |
Asked student to stand or use a chair so not to block the aisle |
|
Closed |
|
27 |
12B |
10/19/00 |
LLE group was handling kerosene/acetic acid samples w/o gloves on |
I told the group that acetic acid is highly coorosive |
|
Closed |
|
28 |
10B |
10/19/00 |
Transported chemicals and a container on the spiral staircase |
Told them it was unsafe and suggested using the stairwell the next time |
|
Closed |
|
29 |
3B |
10/19/00 |
Joking about which valves another group should turn by shouting false alerts to the group member turning a valve during their exp |
Told the person it's not safe to shout false alarms |
|
Closed |
|
30 |
3B |
10/19/00 |
Causing a slipping hazard by not capturing water flow from heat exchanger in a drum. Also a heat hazard if water got hot & was spraying out. |
I showed them how to use the second drum to catch the water. |
|
Closed |
|
31 |
8B |
10/19/00 |
Continuous filtration-someone was holding onto piping for leverage to turn valve |
Told her to not grab on to the pipe |
|
Closed |
|
32 |
4B |
10/19/00 |
Continuous Filtration- not using left hand rule to turn on power to pumps |
Gave friendly reminder but did it again so wrote up |
|
Closed |
|
33 |
10B |
10/19/00 |
The protective wire covering has broken away from the pump switch and exposed the switch wires & interior viscosity capillary experiment |
Suggest getting it taped up |
|
Closed |
|
34 |
12A |
10/24/00 |
Safety crew left safety shower cord hanging instead of clipping it bock onto wall |
Told them to correct it |
|
Closed |
|
35 |
9A |
10/24/00 |
Frayed electric wire on TV-14 Tempunit (Polymer Flow) |
Notified Time Gasperich |
|
Closed |
|
36 |
1A |
10/24/00 |
Valve V-26 on ammonia cooler for the double-pipe heat exchanger has a ding on the knob. The ding is sharp and could cut someone as they turned it. |
Suggest either replacing the valve or the knob, or sanding down the knob |
|
Closed |
|
37 |
12B |
10/26/00 |
Safety Group didn't test safety shower or eye wash station 1st floor by 10:00 am |
Found someone in group and told them |
|
Closed |
|
38 |
4B |
10/26/00 |
Stool in the middle of the walkway near Pumping B |
Asked group to move out of the isle to clear walkway |
|
Closed |
|