PAWS Tracking Results for Cycle 4 for 2000/2001



 
 
 


 
 

Item Number

Group Number

Date PAWS Form Filled Out

Unsafe Act/

Situation/Suggestion

Action Taken/Safety Suggestion

Person Responsible

Open / Closed

Comments

Cycle 4

 

 

 

 

 

 

 

1

3A

1-30-2001

Ladders slide on floors

Need rubber stoppers for extra safety

Gasperich

Closed

New ladders purchased

2

3A

1-30-2001

Floor in basement is very slippery

Sand down glossy finish on floors

Gasperich

Closed

Floor Stripped of wax

3

CMT 1

1-31-2001

Ladders slide on floors

Rubber stoppers on ladders

Gasperich

Closed

New ladders purchased

4

CMT 1

1-31-2001

Bottoms sample port on solvent recovery should be down stream of distillation column, excessive heat

Wear thermal gloves

Caspary

Closed

 

5

1A

2-12-2001

Flammable storage cabinet, plastic funnel used to pour contents back into barrel without grounding

Talked to Dave, No grounding needed

Gasperich

Closed

 

6

11A

2-13-2001

Bio-Sep Room 205: Acid and bases stored in same cabinet

Talk with Bio supervisor

Shonnard

Closed

 Acids and Bases in separate trays.

7

11A

2-13-2001

Bio-Sep Room 205: Sink is too close to unit-water splashes on electrical circuits

Talk with Bio supervisor

Shonnard

Closed

All circuits are protected by GFCI’s.

8

2A/4A

2-20-2001

PDMS manual recommends gas mask be used, none provided

Talked to Dave, recommended for chemicals other than PDMS

Caspary

Closed

 

 

 

 

 

 

 

 

 


Copyright © 1998 by Jason Burtch, Rich Hammond, Jeremiah Konell, and Bryan Vogt