PAWS Tracking Results for Cycle 1 for 1996/97


Item Number Group Number Date PAWS Form Filled Out Unsafe Act / Situation / Suggestion Action Taken/Safety Suggestion Person Responsible Open / Closed
Cycle 1            
1 01a 9/18/96 Glacial Acetic Acid was placed on the lab bench behind the liquid-liquid extraction apparatus. Informed Dr. Pintar in U.O. class meeting. 9/18/96 closed
2 01a 10/1/96 Part of anchoring gasket for batch filtration slurry tank broken off leaving half of the gasket. Showed Tim Gasperich. 10/1/96 closed
3 01a 10/1/96 Spinning part in batch filtration unguarded. Showed Tim Gasperich. 10/1/96 closed
4 02a 10/1/96 Removed tank lid near cooling tower. Possible tripping hazard or chemical hazard. Informed Safety Committee. 10/1/96 closed
5 02a 10/1/96 Tube connection placed on top of radiator near pumping A. Not labeled. Removed from radiator, informed Safety Committee. 10/1/96 closed
6 02b 9/26/96 White sand samples were left out without RTK labeling. It was also left on the counter instead of returned to cabinet. Labeled containers and returned to cabinet. 9/26/96 closed
7 02b 10/3/96 No bottom tray in Ro-Tap machine to catch any material filtered out of the system. Replaced last tray with a solid one. 10/3/96 closed
8 02b 10/3/96 Trays 35/32 stick together so that there is a potential for spilling sand when separating them. Take care when separating the plates.   closed
9 04a 9/23/96 Trash can placed under fire extinguisher. Obstruction of fire extinguisher, 2nd floor UO lab. (Flow Measurement) Trash can moved to other side of room. 9/23/96 closed
10 04a 10/1/96 Grad student entered room 213 without a hard hat. Told student to wear a hard-hat. Student did not comply. 10/1/96 closed
11 04a 10/1/96 Chicken wire on railing in room 213 has sharp pointed edges. Informed Tim Gasperich. 10/1/96 closed
12 05a 9/24/96 Student entered the Ro-Tap room while the Ro-Tap was running, without wearing earplugs. Informed the student that earplugs are necessary. 9/24/96 closed
13 05a 10/1/96 Red oil leaking from red oil manometer in Pumping B apparatus.     closed
14 05b 9/26/96 The weigh tank in the Pumping A experiment leaks badly. Temporarily patched it with duct tape. Permanent fix needed.   closed
15 06a 10/1/96 Fume hood air flow needs to be increased, liquid-liquid extraction area.     closed
16 06a 10/1/96 Two emergency valves in parallel on liquid-liquid extraction. Should only have one for shutdown.     closed
17 06b 9/26/96 Plug for power supply wrapped with electrical tape coming undone, wires will soon become exposed. Told Eric Larson and Tim Gasperich.   closed
18 06b 9/26/96 Leaking bleed valves on the mercury manometer. While pump is running and water flowing through system water drips at a fairly regular rate. Placed a bucket underneath the dripping valve. Brought it to Eric Larson's attention.   closed
19 06b 9/26/96 Red oil leaking from red oil manometer in Pumping B apparatus. Folgers can placed underneath the leak until the manometer can be fixed. Told Eric Larson.   closed
20 06b 10/3/96 Student found not wearing appropriate footwear. Told student of violation. 10/3/96 closed
21 06b 10/3/96 Drain from Pumping B tank empties in basement level drain canal, causes water spills on floor.     closed
22 07b 9/26/96 Ladder over 6 ft. in height was transported from basement to 1st floor by one person. Told person not to do it again and return it using at least 2 people. 9/26/96 closed
23 08a 10/1/96 Cord of stroboscope wrapped with electrical tape, but maintains a poor connection at the inlet of the power into the machine. Care taken to keep the cord bent into the machine to maintain the connection. 10/1/96 closed
24 08b 9/26/96 Air flow out of UO Lab into main building space. High levels of nitrogen would not be detected, contained inside UO Lab. Closed doors leading to main building space. 9/26/96 closed
25 08b 10/3/96 Leaky drum for heat exchanger; rusted near red gate valve on bottom of drum. Labeled and set aside, notified Tim Gasperich.   closed
26 09a 10/1/96 Valve on floor not directly under tank for Pump B. Possible to kick valve open. Piping must be directly under steall tank. 10/1/96 closed
27 09a 10/1/96 Eyewash fountain behind door near basement CM417 entrance.     closed
28 09a 10/1/96 Leaky valves in Pumping B below rotameter furthest from pump and in the T behind the tanks.     closed
29 10a 9/24/96 Clean-up supplies needed: dustpan, sponges at sinks, mop bucket, and floor squeegee. More locks needed for lock-out. Safety Committee alerted by numerous groups.   closed
30 11a 9/24/96 Leaky 55 gal drum Drum was tagged. 9/24/96 closed
31 11a 9/24/96 Hoses stored improperly beneath drier oven. Not wound properly and found on floor. Rewound hoses and placed on shelf beneath drier to prevent tripping hazard. 9/24/96 closed
32 11a 9/24/96 Exposed insulation (fiberglass) on steam purge line at heat exchanger (shell-tube). The exposed area was covered with tape. 9/24/96 closed
33 11a 9/24/96 Upper heat-exchanger, condensate outlet to drain - ball valve had loose nut. Nut was tightened and ball valve was checked to ensure full handle range. 9/24/96 closed
34 11a 9/24/96 Electrical box behind heat-transfer equipment obstructed by cabinet, preventing observance of left-hand rule. Suggested removal of cabinet   closed
35 11a 9/24/96 Metal strap hanging down from L.P.C.W. pipe directly behind shell and tube heat exchanger. Informed Eric Larson and wrote memo to Tim Gasperich informing him of situation.   closed
36 11a 10/1/96 Exposed insulation on steam 125 psig line in various places, dripping purge valve on top shell & tube heat exchanger. Memo written to Tim and Eric. 10/1/96 closed
37 12a 9/24/96 Bent valve stem on drain valve on knock out pot connected with vacuum pump. This causes a misrepresentation of full open. Reported to safety committee.   closed
38 12a 9/24/96 Student was transporting a chemical container without a safety bucket. Instructed student to use a safety bucket from Chem Stores. 9/24/96 closed
39 13a 9/24/96 Drain on 1st floor by chemical storage is no longer a drain and not marked that it doesn't work. Liquid mopped up that didn't go down.   closed