Item Number Group Number Date PAWS Form Filled Out Unsafe Act / Situation / Suggestion Action Taken/Safety Suggestion Person Responsible Open / Closed Comments
Cycle 3              
69 1a 10/1/96 Open electrical box for heating oven Tim Gasperich was informed   closed  
70 8b 10/3/96 Leaky drum for heat exchanger - red gate valve on drum - rusted on bottom near valve created very wet floor Labeled and set aside drum, cleaned up floor. Tim Gasperich was informed.   closed  
71 Dr. Pintar 10/3/96 Ladders left unchained overnight. Put chain around ladders.   closed  
72 11a 12/5/96 Found broken, dirty glassware on floor by L-L extraction Picked up and put in broken glass container   closed  
73 11a 12/5/96 Worn sticker in Liq-Liq extractor. H.F.&R of raffinate stream unreadable Sticker replaced and numbers filled in according to kerosene specs. (Traced pipes to kerosene tanks)   closed  
74 9a 12/10/96 Evacuation route not posted don door in basement next to CM417 lab Route was found and posted on the door   closed  
75 9a 12/10/96 CM417 lab door, when open, blocks the eyewash station and safety shower. Can be hazard to someone using the station. Door may be hinged to open inward rather than outwards   closed  
76 9a 12/10/96 Cabinet blocking fire extinguisher sign, and left-hand rule for panel is violated. Located behind vacuum dryer in basement. Remove cabinet or replace with smaller one.   closed  
77 9a 12/10/96 Liquid-liquid extraction. Did not wear thicker gloves and apron when handling acetic acid Told then to use the proper equipment in the future   closed  
78 9a 12/10/96 While inspecting the emergency shower by pumping B on the second floor, the group performing the liquid-liquid extraction experiment informed us that water was leaking from the ceiling onto their equipment. Tim Gasperich was informed and has decided earlier to find someone to fix the drain   closed  
79 9a 12/10/96 First floor, CSTR, only one person there, and when the professor beckoned the person left the equipment completely unattended Told that person they shouldn't be alone and to pass that on to the group   closed  
80 10a 12/10/96 Step stool at pumping A left in middle of aisle- tripping hazard Moved the stool out of the way   closed  
81 11a 12/10/96 Second floor drain leaks and drips on our equipment Memo written to Mr. Gasperich   closed  
82 11a 12/10/96 Storage of combustibles in plastics containers (process waste) Memo written to Mr. Gasperich   closed  
83 11a 12/10/96 Liquid-liquid extraction, water outlet covered din layer of oily stuff. Possible leak of kerosene. Wiped oil off. No more was seen coming down the pipe. Will check again in future.   closed  
84 12a 12/10/96 Drain on first floor in front of yellow fire cabinets is not an operable drain. It should be labeled as such or covered over.     closed  
85 12a 12/10/96 Bench next to CSTR experiment. Too many electric cords and article not used in lab. Example chart recorder, agitator, heater Put items away and referred to Safety Group   closed  
86 9b 12/12/96 The second floor of UO lab has neither a safety shower or extinguisher. Put a fire extinguisher up there at least.     closed  
87 9b 12/12/96 Drain from first floor by safety shower on the south side leaks. Fix leaks. Bucket put under drain for quick fix.   closed  
88 9b 12/12/96 The drain in the first floor of the UO lab on the north end by the shower near sink is no longer a drain. Stencil on the floor "Not a drain."     closed  
89 10b 12/12/96 There is a waste container for ethanol, kerosene and acetic acid under the bench near the lab office. Shouldn't this flammable material be stored in the flammable liquids cabinet. Notify Safety Group.   closed  
90 9a 12/12/96 The eyewash by the stairs in the basement began to continually leak after we inspected it. Placed a bucket under the eyewash and notified Tim Gasperich.   closed  
91 TA's 12/17/96 PDMS, room 107. Person had retyped procedure for PDMS. Told the person to cease using typed procedure. Error in typing could cause error in experiment.   closed  
92 9b 1/23/97 The distillate sampling tube on the distillation column drips onto a pump. The distillate is flammable. After sample valve is shut, fluid is allowed to drain completely into a sample container taking about five minutes.   closed  
93 9b 1/23/97 Safety signs concerning hygiene need to be put on all doors exiting UP lab. Sign designs presented and scrapped at meeting. Mr. Caspary indicated he would find a suitable professional sign paid by the UO budget.   closed  