Item Number |
Group Number |
Date PAWS Form Filled Out |
Unsafe Act / Situation / Suggestion |
Action Taken/Safety Suggestion |
Person Responsible |
Open / Closed |
Comments |
Cycle 1 |
|
|
|
|
|
|
|
1 |
1B |
9/30/99 |
From Pumping B down to vacuum drying there was a water leak from pumping B calibrating the manometer |
Told Pumping B about it; Cleaned up splash. |
|
Closed |
|
2 |
1B |
9/30/99 |
Single pass heat exchanger 4-way union is leaking water onto floor - slip hazard |
Repair leaky connection |
|
Closed |
|
3 |
13B |
9/30/99 |
Basement First Aid kit is missing Red Cross Cotton and Paper Cups |
Replace these items |
|
Closed |
|
4 |
11B |
9/30/99 |
Safety Shower on second floor is leaking by door 105 |
Fix valve or shower head. Replace? Probably worn out seals |
|
Closed |
|
5 |
13B |
9/30/99 |
In UO Control Room, fire extinguisher has no update tag and no gauge on it |
Replace with extiguisher that has a gauge and refill date tag. |
|
Closed |
|
6 |
13B |
9/30/99 |
Single pass heat exchanger, continuous water leakage from pipe |
Suggestion is to use a bucket |
|
Closed |
|
7 |
2B |
9/30/99 |
Polymer flow valve above pump on large experiment. Leaks slowly when turned. Also very tight and hard to turn. |
Told Nick and he said don't worry about it. Should be fixed |
|
Closed |
|
8 |
6B |
9/30/99 |
Spill Pillow on stairway to pail and scale for flow measurement |
Removed pillow from stairway; Not allowing objects on stairway |
|
Closed |
|
9 |
14B |
9/30/99 |
Filtration Experiment pump leaks terribly! |
No action/suggestion given |
|
Closed |
|
10 |
3B |
9/30/99 |
No first aid kit in room 205 |
Mentioned to T.A., said he knew about it, and it is being taken care of. |
|
Closed |
|
11 |
3B |
9/30/99 |
Safety Group left lab (205) with safety shower bucket and mop unattended - obstructed access to shower and eyewash |
Informed group of unattended equipment and moved equipment out of the way |
|
Closed |
|
12 |
3B |
9/30/99 |
Some chemical bottles lacked NFPA rating |
Informed faculty advisor (memo). He said he'd correct it. |
|
Closed |
|
13 |
4B |
9/30/99 |
Previouis group failed to clean equipment. Chemicals left sitting in system. |
System purged with distilled water |
|
Closed |
|
14 |
3B |
9/30/99 |
Telephone were dangling from around eyewash station in room 205 - tripping hazard |
Informed T.A. of hazard |
|
Closed |
|
15 |
12B |
9/30/99 |
Dropped 10mL graduated cylinder and 125 mL Erlenmeyer flask. Both broke |
Swept up broke glass, put in broken glass disposal. Notified Chem. Stores, Safety Group, and Lab Supervisor |
|
Closed |
|
16 |
10B |
9/30/99 |
Valve on steam line has a condensate leak. Valve is on main line |
Valve should be tagged and replaced |
|
Closed |
|
17 |
13B |
9/30/99 |
2nd floor first aid kit's inventory does not match inventory listed in UO safety manual |
Replace kit with one like those found on first floor and basement floor |
|
Closed |
|
18 |
2B |
9/30/99 |
Polymer flow - small viscometer experiment, feed valve from loading vessel is broken (no longer stops at full open/closed position) |
Valve reported. Suggested that the valve or at least valve handle be replaced |
|
Closed |
|
19 |
1B |
9/30/99 |
Batch filtration run-off flowing beyond drain grating and becoming a slip hazard |
Contacted safety team member and group to inform them that a wet floor sign should be posted |
|
Closed |
|
20 |
7A |
9/30/99 |
CSTR group did not have goggles while mixing chemicals |
Told them to wear goggles |
|
Closed |
|
21 |
13B |
9/30/99 |
Bioseparations T.A. (Geoff Rolant) wasn't wearing safety glasses in the lab. |
At the time we didn't know he was a T.A. We should have instructed him to put safety glasses on. |
|
Closed |
|
22 |
4B |
9/30/99 |
CSTR - could see that there was still phenolphthalein in the system left over from Tuesday's lab. |
We had to take the extra time to clean out the lines |
|
Closed |
|
23 |
2B |
9/30/99 |
Pipe leaks near valve going to rotameter on large polymer flow experiment. It drips whenever piping system is being used. |
Have maintenance personnel look at this connection. The methocel solution is very slippery |
|
Closed |
|
24 |
13B |
9/30/99 |
Group 14B did not sign out at end of the day (Filtration experiment) |
Will be notified of this |
|
Closed |
|
25 |
13B |
10/7/99 |
Student wasn't wearing gloves or apron while handling NaOH |
Informed student |
|
Closed |
|
26 |
13B |
10/7/99 |
In UO office B005A, a glass thermometer was mixed in a drawer with metal objects. Possible mercury spill |
cases are needed for all thermometers |
|
Closed |
|
27 |
4B |
10/7/99 |
Transported glassware without bucket |
A bucket was issued |
|
Closed |
|
28 |
13B |
10/7/99 |
Student was transporting inappropiate object up spiral stairs |
Student was informed of infraction |
|
Closed |
|
29 |
13B |
10/7/99 |
Bioseparation Lab TA was not wearing safety glasses |
Told him to wear safety glasses, didn't put them on |
|
Closed |
|
30 |
14B |
10/7/99 |
Need a nosses on water hose, leaky pump |
informed TA |
|
Closed |
|
31 |
13B |
10/7/99 |
Student wasn't wearing goggles |
Informed student |
|
Closed |
|
32 |
3B |
10/7/99 |
No glassware disposal in room 205 |
Notified TA, TA installed one |
|
Closed |
|
33 |
13B |
10/7/99 |
Student wasn't wearing proper footware |
Student was sent home |
|
Closed |
|
34 |
7B |
10/7/99 |
Student was wearing improper clothing which exposed skin. |
Informed student |
|
Closed |
|
35 |
4A |
9/28/99 |
Liquid/Liquid Extraction - student forgot to put safety glasses on after removing goggles after transporting/using chemicals |
Asked them to put safety glasses back on |
|
Closed |
|
36 |
4A |
9/28/99 |
Two students had loose hair |
Asked them to tie it back |
|
Closed |
|
37 |
4A |
9/28/99 |
Fluidization - student did not wear dusk mask when pouring sand |
They used it the next time |
|
Closed |
|
38 |
4A |
9/28/99 |
Six students did not have red dots on safety glasses when they were wearing contacts |
Red dots were supplied by the safety committee |
|
Closed |
|
39 |
4A |
9/28/99 |
Single Pass Heat Exchanger - student was not wearing insulated gloves when operating a steam valve |
Told them where to find insulated gloves and asked them to use them while operating steam valves |
|
Closed |
|
40 |
3A |
9/28/99 |
Cooling Tower - TA was not wearing ear plugs while the cooling tower was running |
Let him know to get ear protection. |
|
Closed |
|
41 |
4A |
9/28/99 |
Fluidization - student did not wear dusk mask when screening sand |
Asked him to wear dust mask when using the Ro-Tap |
|
Closed |
|
42 |
4A |
9/28/99 |
Cooling Tower - instructor was not wearing ear plugs while the cooling tower was running |
Told to put earplugs in, but turned equipment off instead |
|
Closed |
|
43 |
4A |
9/28/99 |
Bioseparations - three student weren't wearing safety glasses in the lab |
Asked them to put safety glasses back on |
|
Closed |
|
44 |
4A |
9/28/99 |
Students weren't wearing a hard hat in B003 |
Asked them to put their hard hat back on |
|
Closed |
|
45 |
TA |
9/28/99 |
Student was transporting glassware without a bucket |
Told them to get a safety carrier |
|
Closed |
|
46 |
4A |
9/28/99 |
Batch Filtration - two group members went to lunch, one left because he had a meeting, resulting in one person left a equipment |
Stayed with him until his group members who were at lunch returned |
|
Closed |
|
47 |
4A |
9/28/99 |
Glassware left on bench top at end of lab period. |
Romulo put it in a drawer |
|
Closed |
Taken care of by next lab period |
48 |
3A |
9/28/99 |
Cooling Tower - Main disconnect switch left in "ON" position for water cooling tower |
Action - switch turned off Suggestion - double check equipment befor leaving lab |
|
Closed |
|
49 |
9A |
9/28/99 |
Flow Measurement - pump has exposed rotating shaft that could catch hair, clothing, or shoelace etc. and result in serious injury |
Supply more guarding--cover with polycarbonate chield or screen |
|
Closed |
|
50 |
9A |
9/28/99 |
Flow Measurement - north side manometer high pressure and bypass valves leak water |
Replace/repair valves |
|
Closed |
|
51 |
4A |
9/28/99 |
PDMS Safety Shower Corner - wire mesh is frayed, loose, sharp, and pokey. Mean to mop, which got itself entangled in it. |
Action - reprimanded mop Suggestion - fix the fencing so that things do not get caught in it |
|
Closed |
|
52 |
4A |
9/28/99 |
1st floor by CSTR has a hole that looks like a drain (painted yellow) but is not a drain |
Paint it in a different color (blue maybe) and the "NOT A DRAIN" sign should be repainted |
|
Closed |
|
53 |
4A |
9/28/99 |
PDMS Safety Shower looks like a drain (painted yellow) but is not a drain |
Paint it in a different color (blue maybe) and a "NOT A DRAIN" sign should be added |
|
Closed |
|
54 |
9A |
9/28/99 |
Flow Measurement - high and low pressure pipes for manometer and orifice plate labeled backwards |
Labeled pipes and valves correctly |
|
Closed |
|
55 |
12A |
9/28/99 |
Safety Shower by south door 105 was dripping |
Notified safety committee and a TA |
|
Closed |
|
56 |
4A |
9/28/99 |
Phone cord in 205 is in the way of the safety shower chain |
Use white clips (like the red cord next to it) to keep phone cord attached to the wall instead of electrical tape |
|
Closed |
|
57 |
4A |
9/28/99 |
Unlabeled bottle on bench |
They labeled it. |
|
Closed |
|
58 |
4A |
9/28/99 |
Vacuum Drying - student was trying to carry a platter of calcium carbonate up the spiral staircase |
Told them to use the outside stair or elevator |
|
Closed |
|
59 |
TA |
9/28/99 |
Group 13A - unlabed chemicals on the bench |
Told them to label it |
|
Closed |
|
60 |
4A |
10/5/99 |
CSTR - student was not wearing goggles when pouring and transporting alcohol for the CSTR experiment |
Asked him to wear safety goggles |
|
Closed |
|
61 |
4A |
10/5/99 |
Student was transporting two pieces of glassware without a bucket |
Told them to put the glassware into a bucket |
|
Closed |
|
62 |
TA |
10/5/99 |
Batch Filtration - student was going to insert stir stick into tank without deactivating agitator |
Prevented student from putting broomstick in tank with the mixer on |
|
Closed |
|