PAWS Tracking Results for Cycle 5 for 1999/2000



 


 

Item Number

Group Number

Date PAWS Form Filled Out

Unsafe Act / Situation / Suggestion

Action Taken/Safety Suggestion

Person Responsible

Open / Closed

Comments

Cycle 5

 

 

 

 

 

 

 

1

3A

1/25/00

Student did not have hard-hat on

Suggested student leave lab and get a hard-hat

 

Closed

 

2

3A

1/25/00

"Emergency Shower and Eyewash" sign fell when checking eyewash on second floor

Do not use tape, screw it to the wall

 

Closed

 

3

3A

1/25/00

Shower in bioseparations lab fails to shut off

Dave Caspary has been made aware of the situation

 

Closed

 

4

11A

1/25/00

The kW gauge of the 25A Industrial Analyzer in need of repair. (Pumping A)

Glass removed and replaced with clear tape

 Gasperich

Closed

 

5

12A

1/25/00

Improper connection on bioreactor, solution spilled over counter

Cleaned up spill.  Need better labeling of ports.

 

Closed

 

6

3A

1/25/00

"Shower and Eyewash" sign on first floor, south end, was lying on the floor

Sign readhered to wall with double sided adhesive 

 

Closed

 

7

1B

1/27/00

Person came down spiral stairway with beaker

Recommended proper way to handle and carry glassware

 

Closed

 

8

1B

1/27/00

During emergency shutdown, PDMS did not shut down 

Made sure PDMS knew their emergency shutdown procedure

 

Closed

 

9

4B

1/27/00

Only one person running equipment

Told them to get another team member

 

Closed

 

10

7B

1/27/00

Leaking valve/pipe near viscometer table near PDMS reactor

Needs to be blinded

 Gasperich

Closed

 

11

12B

1/27/00

Two groups did not sign out

Remind groups of importance of signing out

 UO Faculty

Closed

 

12

12B

1/27/00

First floor transport of fluid in a beaker without a bucket

Use a bucket

 

Closed

 

13

6A

3/21/00

Phone in the basement office does not have current emergency phone numbers displayed

Placed sticker on phone and updated phone list on wall.

 

Closed

 

14

6A

3/21/00

Fire extinguisher in Rm 205 not clearly labeled

Put a "fire extinguisher" sticker sign above it

 

Closed

 

15

10A

3/21/00

Kerosene tank on liq-liq extraction has differing labels pertaining to flammability

Told safety group

 

Closed

 

16

6A 

3/21/00

Student had jacket in the laboratory at the shell and tube heat exchanger site

Student told to remove jacket from lab 

 

Closed 

 

17

5A

3/21/00

Broken glass container sitting on top of empty barrels

Safety team moved broken glass container

 

Closed

 

18

10A

3/21/00

Faculty advisor not wearing hard hat

Told safety group

 

Closed

 

19

6A

3/21/00

Solvent recovery groups left basement unattended

Went to control room and sent 2 people to the basement

 

Closed

 

20

13A

3/21/00

PDMS - 3 guys by viscometer but no one at the aparatus on the floor

Tell one of them to sit by PDMS Reactor

 

Closed

 

21

5B

3/23/00

PDMS was left unattended

Told TA

 

Closed

 

 22

5B

3/23/00

Student did not have hard hat on

Told him to put it on

 

Closed

 

 23

1B

3/23/00

Leaky union near RV-70

Repair

 

Open

 

 24

2B

3/23/00

Dow 245 Fluid transfer can leaks

Replace or fix can

 

Closed

 

 25

9B

3/23/00

Caught student sleeping in lab

Woke him up and warned him about safety hazards of his actions

 

Closed

 

 26

9B

3/23/00

Emergency Route posted on south basement door needs to be re-laminated

Re-laminate and re-post

 

Closed

 

 27

1B

3/23/00

Flammable waste container emitting toluene fumes

Placed container in fume hood 

 

Closed

 

 28

1B

3/23/00

Two people entered lab without helmets or safety glasses

Told TA

 

Closed

 

 29

5B

3/23/00

Top steam valve for LLE leaks when opened

Fix it

 

Closed

 

 30

5B

3/23/00

No soap dispenser at sink near LLE

Install soap dispenser

 

Closed

 

31

9B

3/23/00

Doorknob entering PSCC is difficult to turn.

Replace doorknob

 

Closed

 

32

10A

3/28/00

Steam shut-off to liquid-liquid extraction has a small leak

Re-seal or replace valve

 

Closed

 

33

6A

3/28/00

Student dropped two glass flask caps while running solvent recovery

Broken glass swept up and put into broken glass container

 

Closed

 

34

9B

3/30/00

PDMS group was putting paper towels with toluene on them in the regular waste containers

Told to use flammable waste container

 

Closed

 

35

9B

3/30/00

Person caught running in bioseparations laboratory

Told to stop

 

Closed

 


Copyright © 1998 by Jason Burtch, Rich Hammond, Jeremiah Konell, and Bryan Vogt